Commissioning Services

Commissioning is where the complete data-centre infrastructure must perform as one integrated system—not simply as a collection of individually tested components.

XPM manages the full commissioning lifecycle, from design and factory verification through energisation, functional testing, integrated systems testing and final handover. Our teams work alongside the client, OEMs, general contractor and operations personnel to verify that every system performs safely, reliably and under real operating conditions.

Commissioning Management

Commissioning strategy and execution plans

Commissioning programme development and sequencing

Systems, equipment and responsibility matrices

Design, specification and sequence-of-operation reviews

Test-script preparation, review and approval

Commissioning risk and interface management

OEM, contractor and client coordination

Progress reporting, issue tracking and escalation

Commissioning document control and evidence management

Factory and Pre-Delivery Testing

Factory Acceptance Testing

Factory Witness Testing

OEM manufacturing and quality surveillance

Control-panel and switchgear testing

Generator load-bank and performance testing

Chiller performance testing

Integrated package testing

Inspection of equipment before shipment

Defect management and release-to-ship approval

Generator and Emergency-Power Systems

Generator mechanical and electrical inspections

Fuel, lubrication, cooling and exhaust systems

Starting systems and batteries

Generator controls and protection settings

Synchronisation and paralleling

Load sharing and load-shedding sequences

Resistive and reactive load-bank testing

Black-start and utility-failure testing

Automatic mains-failure sequences

N+1 and redundant-system operation

Generator failure and recovery scenarios

Fuel polishing, transfer and day-tank systems

Emergency shutdowns, alarms and interlocks

Full-load endurance and step-load testing

Electrical Systems

Utility and grid connections

HV and MV systems

Transformers and protection systems

MV and LV switchgear

Busduct and busway systems

Uninterruptible Power Supplies

Battery systems and autonomy testing

Static Transfer Switches

Automatic Transfer Switches

Power Distribution Units

Remote Power Panels and rack-power distribution

Earthing, grounding and bonding

Protection coordination and relay testing

Metering and power-quality verification

Electrical Power Monitoring Systems

Emergency Power-Off systems

Mechanical and Cooling Systems

Chillers and packaged cooling equipment

Cooling towers, dry coolers and heat rejection

Primary and secondary chilled-water pumps

Chilled-water distribution systems

CRAH and CRAC units

In-row and rear-door cooling

Coolant Distribution Units

Direct-to-chip and liquid-cooling interfaces

Water treatment and filtration

Pressurisation and expansion systems

Valves, actuators, strainers and control devices

Testing, adjusting and balancing

Flow, pressure and temperature verification

Cooling redundancy and failure-mode testing

Controls and Life-Safety Systems

Building Management Systems

Electrical Power Monitoring Systems

PLC and SCADA controls

Generator and chiller control integration

Fire-alarm systems

VESDA and early-warning smoke detection

Fire-suppression systems

Water and fuel leak detection

Security and access-control interfaces

Alarm, interlock and notification testing

Trend-log and sequence verification

Data-Hall and White-Space Systems

Power distribution through to rack interfaces

Busway tap-off units and rack PDUs

Data-hall environmental performance

Airflow and containment verification

Hot-aisle and cold-aisle performance

Temperature and humidity mapping

Load simulation and thermal testing

BMS, EPMS and DCIM integration

Capacity and redundancy verification

Integrated Systems Testing

XPM tests how the facility responds when systems are placed under pressure, including:

Complete utility-power failure

Generator start and transfer

Failure of an individual generator

UPS and battery autonomy

Switchgear and protection operations

Chiller or pump failure

Loss of communications or controls

Fire and emergency events

Redundant-path operation

Load shedding and recovery

Simultaneous electrical and mechanical failures

Return to normal operation after an event

Handover and Operational Readiness

Defect, punch-list and snag management

Commissioning records and test certification

Systems manuals and turnover documentation

Operations and maintenance manual reviews

Client and facilities-team training

SOP, MOP and EOP development

Asset registers and warranty tracking

Final performance reporting

Deferred and seasonal testing

Post-handover troubleshooting and support

From the first factory test to the final integrated systems test, XPM verifies that the complete facility performs safely, reliably and as designed—before responsibility passes to the client’s operations team.